Magnetic Levitation Blower – Nuoshui Environmental
The YF series magnetic levitation blower utilizes active mognetic bearings and a high-speed permanent mognetsynchronous motor.
Best services
Customer-centric, offering rapid response, tailored solutions, and end-to-end support.
Rich in experience
Industry veterans with solid expertise and strong risk anticipation.
Quality assured
Globally certified standards with rigorous end-to-end quality control.
Excellent team
A team of elites—collaborative, innovative, and committed to delivering client value.
YF ACTIVE MAGNETIC BEARING TECHNOLOGY •EFFICIENCY ADVANTAGE
Magnetic Levitation Blower.
The YF magnetic levitation blower integrates an active magnetic bearing system, high-speed permanent magnet motor, three-dimensional aerodynamic impeller, dedicated VFD and intelligent control platform into one compact high-efficiency blower system.
Lower energy use.Lower operating cost.
Energy-saving reference compared with conventional Roots blower technology under applicable operating conditions.
YF•MAGNETIC LEVITATION SERIES
No mechanical contact.No conventional friction.
Mechanical Contact in the Bearing System Active electromagnetic force supports the rotor without conventional bearing contact, reducing friction and eliminating the need for bearing lubrication.
|
Non-Contact Rotation |
Oil-Free Operation | Frequent Start / Stop |
Safe Shutdown |
![]() |
![]() |
![]() |
![]() |
| The active magnetic bearing keeps the high-speed rotor suspended without conventional mechanical bearing contact. | No lubricating oil is required in the magnetic bearing system, supporting clean air delivery and simplified maintenance. | The magnetic suspension architecture supports repeated start-stop operation without conventional bearing wear. | Self-power generation maintains rotor levitation during a power interruption until the system completes a safe stop. |
CORE TECHNOLOGY
Five technologies.One integrated blower.
The aerodynamic, motor, bearing, power-safety and variable-frequency systems are designed together as a complete high-speed blower platform.
OPERATING PRINCIPLE
Levitate. Accelerate. Move air.
The YF Series uses active magnetic bearings and a high-speed permanent-magnet synchronous motor to directly drive the aerodynamic impeller.
The dedicated VFD and PLC control system adjust operating speed and airflow according to process demand.
SELECTION PARAMETERS
Representative YFC models.
The table below provides representative flow-rate references.For final selection, confirm the required airflow and discharge pressure with the YF engineering team.
Selection note:
These are representative values from the YFC product selection information rather than the full model matrix. Final blower selection should be confirmed according to required pressure, airflow, altitude, temperature and operating conditions.
ENGINEERING & INNOVATION
Technology supported by continuous development.
YF continues to develop high-speed rotating equipment,magnetic levitation technology and intelligent control solutions for energy-efficient industrial air systems.
Magnetic levitation technology development High-speed permanent magnet motor engineering Aerodynamic impeller optimization Intelligent equipment control
Need a magnetic levitation blower for your project?
Send us your required airflow, discharge pressure, application and operating conditions. Our engineering team can help select the appropriate YFC configuration.
Magnetic Levitation Blower Model Selection
机型选型表已完整展开,所有型号与压力段数据全部显示,不再只保留局部截图。
| Model | Power kW | 25 KPa | 30 KPa | 35 KPa | 40 KPa | 50 KPa | 60 KPa | 70 KPa | 80 KPa | 90 KPa | 100 KPa | 110 KPa | 120 KPa | 130 KPa |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YFC15 | 15 | 31 | 26 | 23 | 20 | 17 | 14 | - | - | - | - | - | - | - |
| YFC18.5 | 18.5 | 38 | 32 | 28 | 25 | 21 | 18 | - | - | - | - | - | - | - |
| YFC22 | 22 | 46 | 39 | 34 | 30 | 24 | 21 | 18 | 16 | - | - | - | - | - |
| YFC30 | 30 | - | - | - | 40 | 33 | 28 | 25 | 22 | - | - | - | - | - |
| YFC37 | 37 | - | - | - | 50 | 41 | 35 | 31 | 28 | - | - | - | - | - |
| YFC45 | 45 | - | - | - | 61 | 50 | 43 | 37 | 33 | 30 | 28 | 26 | 24 | - |
| YFC55 | 55 | - | - | - | 74 | 61 | 52 | 46 | 41 | 37 | 34 | 32 | 30 | - |
| YFC75 | 75 | - | - | - | 101 | 83 | 71 | 62 | 56 | 51 | 47 | 43 | 40 | - |
| YFC90 | 90 | - | - | - | - | 100 | 85 | 75 | 67 | 61 | 56 | 52 | 48 | - |
| YFC110 | 110 | - | - | - | - | 122 | 104 | 91 | 82 | 74 | 68 | 63 | 59 | - |
| YFC132 | 132 | - | - | - | - | 146 | 125 | 110 | 98 | 89 | 82 | 76 | 71 | 67 |
| YFC145 | 145 | - | - | - | - | 161 | 137 | 121 | 108 | 98R | 90 | 84 | 78 | 73 |
| YFC160 | 160 | - | - | - | - | 177 | 152 | 133 | 119 | 108 | 99 | 92 | 86 | 81 |
| YFC185 | 185 | - | - | - | - | 205 | 175 | 154 | 138 | 125 | 115 | 107 | 100 | 94 |
| YFC200 | 200 | - | - | - | - | - | 189 | 166 | 149 | 135 | 124 | 115 | 108 | 101 |
| YFC220 | 220 | - | - | - | - | - | 208 | 183 | 164 | 149 | 137 | 127 | 118 | 111 |
| YFC250 | 250 | - | - | - | - | - | 237 | 208 | 186 | 169 | 155 | 144 | 135 | 127 |
| YFC280 | 280 | - | - | - | - | - | 265 | 233 | 208 | 189 | 174 | 161 | 151 | 142 |
| YFC300 | 300 | - | - | - | - | - | 284 | 249 | 223 | 203 | 186 | 173 | 161 | 152 |
| YFC315 | 315 | - | - | - | - | - | 298 | 262 | 234 | 213 | 196 | 181 | 170 | 159 |
| YFC350 | 350 | - | - | - | - | - | 331 | 291 | 260 | 237 | 217 | 202 | 188 | 177 |
| YFC400 | 400 | - | - | - | - | - | 379 | 333 | 298 | 270 | 248 | 230 | 215 | 202 |
Note: representative YFC-series selection values from the provided table.